Number |
Type |
Application
Schematics & Application
Notes for Electronic Loads
Schematics
are for all EE301xx
& EE151xx
Series Electronic Loads |
|
ANEE-000 |
PDF |
Mechanical
Dimensions, for Electrical Mounting and Hookup |
|
ANEE-100 |
PDF |
Block
Diagram,
Internal
Electronic Block Diagram ( schematic ) of EE301xx
& EE151xx Electronic Loads pin-outs and connection for power and
ground, Pots & External signals |
|
ANEE-101 |
PDF |
Connectors,
Electronic Load Connectors J1 & J2 what each pin does.
impedance & IO & Voltage & Current EE151xx
& EE301xx series |
|
ANEE-102 |
PDF |
Powering
the electronic
Loads,
The
main bias power that is required to run the electronic circuits in the electronic loads for earthier regulated or unregulated voltage. 12 Volts /
14-30 Volts |
|
ANEE-103 |
PDF |
Constant
Current Operation,
Analog Operation of loads EE151xx & EE301xx series |
|
ANEE-104 |
PDF |
Current
Limit the Electronic
Loads,
Limit the Current the Electronic
Load can draw |
|
ANEE-105 |
PDF |
Snubber-1-2,
For voltage and spike limiting. Part 1 of 2 this is for use with mechanical
contactors and our electronic loads. Schematics of Snubbers Schematics |
|
ANEE-106 |
PDF |
Snubber-2-2,
For voltage and spike limiting. Part 2 of 2 this is for use with mechanical
contactors and our electronic loads. How to test and set a Snubber Documentation |
|
ANEE-107 |
PDF |
Charging
Batteries 1-2, Using an electronic load to charge high power batteries, Part 1 of 2 This works only with our electronic loads & has option CC added to
the load. Schematics |
|
ANEE-108 |
PDF |
Charging
Batteries
2-2,
Using an electronic load to charge high power batteries, Part 2 of 2 This works only with our electronic loads & has option CC added to
the load. Documentation |
|
ANEE-109 |
PDF |
Primary
Battery Testing,
For testing a single cell, Go / No-Go Testing |
|
ANEE-110 |
PDF |
Summing
Current Monitors,
When connecting multi-loads in parallel you can sum the current monitors
of all loads to a summing-amp creating a single total current of all loads |
|
ANEE-111 |
PDF |
Deep
Cycle Battery
Discharge, For
constant current discharge of secondary batteries into the deep or ultra
low voltage region of the battery |
|
ANEE-112 |
PDF |
External
LCD Display, For monitoring
UUT test terminal voltage at load, for 0-50/150 Volts
using the constant current operation mode of the electronic load |
|
ANEE-113 |
PDF |
External
LCD Display, For monitoring
UUT test terminal current at load, for 0-20/40/80 Amps
using the constant current operation mode of the electronic load |
|
ANEE-114 |
PDF |
External
LCD Display, For monitoring
UUT test terminal current at load, for 0-20/40/80 Amps
using the qusi-constant power operation mode of the electronic load |
|
ANEE-115 |
PDF |
Step
/ Slew
Testing,
For doing a constant current step test or testing the slew rate of a
device |
|
ANEE-116 |
PDF |
External
Fixed
Resistors,
For controlling current & voltage startup of the electronic load |
|
ANEE-117 |
PDF |
Switch
Testing, For
toggle & power switch contact current rating test using constant
current |
|
ANEE-118 |
PDF |
External
Current
Shunt,
Best method of using a current shunt with electronic loads |
|
ANEE-119
|
PDF
|
Thermal
Trip, Using the
internal thermal trip of the electronic load to an external circuit |
|
ANEE-120
|
PDF
|
Series
Battery
Charging,
For using electronic loads in series operation |
|
ANEE-121 |
PDF |
Master
& Slave Operation,
Using a master load to drive & control slave loads |
|
ANEE-122 |
PDF |
Parallel
Operation, Using
the qusi-power operation mode with an external pot |
|
ANEE-123 |
PDF |
Lamp
/ Filament,
Constant Power Driver for lamps and filaments, DC lights, |
|
ANEE-124 |
PDF |
Fuel
Cell
System,
Connection for testing a fuel cell system |
|
ANEE-125 |
PDF |
External
Pots, Using
External pots for controlling load current and voltage start-up |
|
ANEE-126 |
PDF |
Solar
Cell &
TPV,
Testing of solar cells & thermal cell Go/No-Go testing, using a lamp
source |
|
ANEE-127 |
PDF |
I2C Cable,
Cable for interfacing the PC parallel port and I2C device using I2C-OCX
& I2CRTD |
|
ANEE-128 |
PDF |
Isolators, Using
voltage isolators with electronic loads / floating electronic loads |
|
ANEE-129 |
PDF |
Laser
Diode Driver,
Control of a high power laser diode using constant current for age time
& resistance |
|
ANEE-130 |
PDF |
Generator,
Testing DC generators |
|
ANEE-131 |
PDF |
Motor
Speed
Control,
For Speed control of a DC motor & testing |
|
ANEE-132 |
PDF |
Speaker
Coil
Throw,
For test the deflection of a speaker coil |
|
ANEE-133
|
PDF
|
Heater
Control,
For non-overshoot type of heater control using constant current |
|
ANEE-134
|
PDF
|
Battery
Charging & Discharging
Digital,
Using a computer digital controlled electronic load for charging a battery
bank with a power supply & Discharging a battery bank with the same
electronic load. |
|
ANEE-135
|
PDF
|
Battery
Charge
Digital,
Using a computer digital controlled electronic load for charging a battery
bank with a power supply. |
|
ANEE-136
|
PDF
|
Battery
Discharge
& Charging Using AUXs Digital,
Using a computer digital controlled electronic load for charging a battery
bank with a power supply and discharging a battery bank |
|
ANEE-137
|
PDF
|
Digital
Control
UUT,
Using a computer digital control electronic load for with a power supply. |
|
ANEE-138
|
PDF
|
Super
Capacitor
Discharging Digital,
Using a computer digital controlled electronic load for discharging a
super capacitor with a power supply |
|
ANEE-139
|
PDF
|
Fan
Constant
Speed,
using a load to control fan current with high ripple voltage &
changing voltage levels or just jumpy voltages. |
|
ANEE-140
|
PDF
|
Diode
Junction
Testing Digital,
Using a computer digital controlled electronic load for testing high power
diode junction. |
|
ANEE-141
|
PDF
|
Switch
Junction
Testing Digital,
Using a computer digital controlled electronic load for testing switch
contact junctions. |
|
ANEE-142
|
PDF
|
Dendrites
& Fracticals Growth
Digital,
Using a computer digital controlled electronic load for testing the growth
rate of dendrites on cathodes. |
|
ANEE-143
|
PDF
|
AC
Electronic Load
Digital,
Using a DC Electronic Load that is digital controlled to make a AC
Electronic Load that is digital controlled. Here is a simple low cost way
of doing it. |
|
ANEE-144
|
PDF
|
Constant
Voltage
Operation,
for all types of loads EE151xx & EE301xx series |
|
ANEE-145
|
PDF |
Bidirectional
Current
Operation,
for all types of loads EE151xx & EE301xx series |
|
|
|
|
|
Request
Only
|
DOC
|
Dendrite
formation in Alkaline
Batteries,
The article covers how and why dendrites are formed in the batteries and
how they may be stopped using current technology. |
|
EES-100
|
PDF
|
Electronic
Load Control
Software,
Over view of EES-100 the digital software
how it works and all functions and options for testing. Constant Current /
Constant Power / Constant Resistance / Constant Voltage / can be used for
both charging and discharging of batteries. |
|
|
|
|